XTPR2P5BC1

Eaton XTPR2P5BC1 Manual Motor Protector

 
Alternative Views:


The Eaton XTPR2P5BC1 manual motor protector is adjustable from 1.6 to 2.5 AMPS, has single phase sensitivity and mounts to standard 35MM din rail. Class 10 tripping protection (trips in 10 seconds or less) is standard on all XTPR motor starters along with a rotary operated on/off handle. Front and side mounted auxiliary contacts can be added to the XTPR2P5BC1 in addition to undervoltage trips to suit any motor protection needs

XTPR2P5BC1 Datasheet

Need a slightly lower AMP range? Click here to see the XTPR1P6BC1
Need a slightly higher AMP range? Click here to see the XTPR004BC1

List Price: $217.00
Our Price: $96.27
Savings: $120.73
Stock Items : Ships same day up until 4 p.m. EST
Non-Stock Items : 1-2 days for item to ship for standard delivery

Quantity in Stock:17

Product Code: XTPR2P5BC1


Eaton XTPR Auxiliaries:


Eaton XTPR Undervoltage Trips:


Qty:  
Description Detailed Specifications
 
The Eaton XTPR2P5BC1 is UL listed under UL 508 as manual motor protectors. They provide an economical solution for applications requiring simple manual starting and stopping of motors. When used as a manual starter, they are typically installed in an enclosure. Many enclosures are offered as accessories for the MMPs. Separate short circuit protective devices, such as circuit breakers or fuses, are wired ahead of the MMPs. The short-circuit protective device should be sized per the NEC and should not exceed 400% of the maximum FLA dial setting of the MMP.

A UL 508 Type E self protected manual combination starter/motor controller consists of a single device possessing four essential elements: disconnect, short circuit protection, motor controller, and motor overload protection such as the XTPR2P5BC1. Some MMPs require use of a line side adapter for this type of approval. When tested as an official combination by UL, this device takes the place of a fuse-starter or breaker/starter.
Technical Specifications
  • ON/OFF rotary handle with lockout provision
  • Visible trip indication
  • Class 10 overload protection
  • Phase loss sensitivity
  • Ambient temperature compensation to IEC/EN 60947, VDE 0660
  • Fixed short-circuit trip— 14 times maximum setting of overload FLA dial
  • Type 2 coordination per IEC 947
  • Identification markers standard on starter faceplate
  • Motor applications from 0.1A to 65A
  • Built-in heater and magnetic trip elements to protect the motor