Allen Bradley 190E-AND2-CB16X combination starter
 
Allen Bradley 190E-AND2-CB16X self protected starter rated for 2 H.P @ 230 volt and 5 H.P. @ 460 volt 3 Phase (100-C09D10) with an adjustable manual starter from 1.0 to 1.6 AMPS (140M-C2E-B16) and a 110v50Hz/120v60Hz AC coil - 3 power poles with 1 N.O. base mounted auxiliary contact - screw terminals and base or DIN rail mounting

190E-AND2-CB10X Datasheet

Need help finding the coil voltage? Click here to see a picture to help determine the location of the coil voltage for this starter.

List Price: $480.00
Our Price: $210.47
Savings: $269.53
Note: IMC-Direct is not an authorized Rockwell Automation distributor
Note: This product does not come with a Rockwell Automation warranty

Quantity in Stock:(Out of Stock)

Availability : Stock - Can ship today if ordered prior to 4 p.m. EST
Product Code: 190E-AND2-CB16X
Qty:

Description Detailed Specifications
 
The 190E motor controllers can be used in a variety of applications. These starters can be used in a group motor application or as a stand-alone product without any additional short-circuit protection in the motor branch circuits. Most of the 140M-C/D motor protection circuit breakers used in the 190E/191E starters are UL Listed as a manual Type E self-protected combination motor controller. Although there are many tests involved, one of the critical tests a self-protected combination motor controller must pass is to perform 6000 electrical ops. and an additional 4000 mechanical ops. after a short circuit. By definition, a Type F combination motor controller consists of a Type E manual self protected combination motor controller and a magnetic or solid-state motor controller (such as a 100-C contactor or an SMC). As with a manual Type E self-protected combination motor controller, additional short-circuit protection is not required for the individual motor circuits. A combination of a 140M manual self protectd combination motor controller and 100-C contactor can be listed as a Type E self-protected combination motor controller. In this case, the 140M and 100-C must pass the additional 6000 electrical and 4000 mechanical operational test. In some cases, this may require over sizing of the 140M motor protection circuit breaker or the 100-C contactor to achieve weld-free performance and meet the additional life requirements.
Technical Specifications
  • Current range: 0.1...43 A
  • Bulletin 190E/191E modular Eco starters
  • Bulletin 190S/191S Pre-wired compact starters
  • Uses Bulletin 140M motor protection circuit breakers (MPCBs) and Bulletin 100-C or 100-K contactors
  • cULus Listed for control and protection of motor loads
  • type 1 or Type 2 Coordination
  • Mounts to top hat rail(s) or screw mounts